Title: Design and analysis of a new tactile device featuring Magneto-Rheological fluid in control force of robotic surgery
Authors: Do Xuan Phu 
Le Tran Huy Thang 
Keywords: Magneto-Rheological Fluid (MRF);MR skin;MR actuator;Optimization;Pressure control;Tactile device;Deformation change
Issue Date: 2019
Series/Report no.: Science and Technology development Journal, ISSN 1859-0128, Vol. 22(2),;
Abstract: 
In this paper, a new artificial skin tissue device which can emulate the stiffness of several organs of human is proposed and analyzed utilizing magneto-rheological (MR) fluid (MR skin). The proposed skin could be applied for the robot-assisted surgery manipulated by haptic devices as a controllable tactile sensor. The method in this paper is design of multi- embedded valve networks inside the structure of the master actuator. These valves use the flow mode and shear mode of MR for pressure control. Deformation equation of the MR skin is derived and the external force contacting the MR skin is also analyzed. After formulation, the proposed tactile display is optimized by using the finite
element method software (ANSYS ADPL). It is shown via the optimization that the results can satisfy the initial requirements of the design. From the simulation results, the adjacent coils with similar setup show outstanding results compared with adjacent coils with discordant setup. This directly indicates that the proposed MR skin structure is feasible in the manufacturing and is applicable to haptic devices, especially those used for robotic surgery
pp 264-274
URI(1): http://epub.vgu.edu.vn/handle/dlibvgu/138
DOI: 10.32508/stdj.v22i2.1342
Appears in Collections:ARTICLE/BOOK PUBLICATION

Files in This Item:
File SizeFormat
Design and analysis of a new tactile device featuring Magneto-Rheological fluid in control force of robotic surgery.pdf2.06 MBAdobe PDFView/Open
Show full item record

Page view(s)

81
checked on Aug 23, 2025

Download(s)

56
checked on Aug 23, 2025

Google ScholarTM

Check

Altmetric

Altmetric


Items are protected by © Copyright of Vietnamese - German University Library

© Copyright 2020 by Vietnamese - German University Library.
Add: Ring road 4, Quarter 4, Thoi Hoa Ward, Ben Cat City, Binh Duong Province
Tel.:(0274) 222 0990. Ext.: 70206