Skip navigation


  • DSpace logo
  • Home
  • Collections
  • Researcher Profile
  • Explore by
    • Researcher Profile
  • VGU library
  • Help
  • User Guide
  • Sign on to:
    • My DSpace
    • Receive email
      updates
    • Edit Account details

VGU RESEARCH REPOSITORY


Please use this identifier to cite or link to this item: https://epub.vgu.edu.vn/handle/dlibvgu/138
DC FieldValueLanguage
dc.contributor.authorDo Xuan Phuen_US
dc.contributor.authorLe Tran Huy Thangen_US
dc.date.accessioned2020-03-12T16:55:50Z-
dc.date.available2020-03-12T16:55:50Z-
dc.date.issued2019-
dc.identifier.urihttp://epub.vgu.edu.vn/handle/dlibvgu/138-
dc.description.abstractIn this paper, a new artificial skin tissue device which can emulate the stiffness of several organs of human is proposed and analyzed utilizing magneto-rheological (MR) fluid (MR skin). The proposed skin could be applied for the robot-assisted surgery manipulated by haptic devices as a controllable tactile sensor. The method in this paper is design of multi- embedded valve networks inside the structure of the master actuator. These valves use the flow mode and shear mode of MR for pressure control. Deformation equation of the MR skin is derived and the external force contacting the MR skin is also analyzed. After formulation, the proposed tactile display is optimized by using the finite element method software (ANSYS ADPL). It is shown via the optimization that the results can satisfy the initial requirements of the design. From the simulation results, the adjacent coils with similar setup show outstanding results compared with adjacent coils with discordant setup. This directly indicates that the proposed MR skin structure is feasible in the manufacturing and is applicable to haptic devices, especially those used for robotic surgery pp 264-274en_US
dc.language.isoenen_US
dc.relation.ispartofseriesScience and Technology development Journal, ISSN 1859-0128, Vol. 22(2),;-
dc.subjectMagneto-Rheological Fluid (MRF)en_US
dc.subjectMR skinen_US
dc.subjectMR actuatoren_US
dc.subjectOptimizationen_US
dc.subjectPressure controlen_US
dc.subjectTactile deviceen_US
dc.subjectDeformation changeen_US
dc.titleDesign and analysis of a new tactile device featuring Magneto-Rheological fluid in control force of robotic surgeryen_US
dc.typeArticleen_US
dc.identifier.doi10.32508/stdj.v22i2.1342-
item.languageiso639-1other-
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:ARTICLE/BOOK PUBLICATION
Files in This Item:
File SizeFormat
Design and analysis of a new tactile device featuring Magneto-Rheological fluid in control force of robotic surgery.pdf2.06 MBAdobe PDFView/Open
Show simple item record

Page view(s)

81
checked on Aug 23, 2025

Download(s)

56
checked on Aug 23, 2025

Google ScholarTM

Check

Altmetric

Altmetric


Items are protected by © Copyright of Vietnamese - German University Library

© Copyright 2020 by Vietnamese - German University Library.
Add: Ring road 4, Quarter 4, Thoi Hoa Ward, Ben Cat City, Binh Duong Province
Tel.:(0274) 222 0990. Ext.: 70206