Please use this identifier to cite or link to this item: https://epub.vgu.edu.vn/handle/dlibvgu/79
DC FieldValueLanguage
dc.contributor.authorLouis WY Liuen_US
dc.contributor.authorAbhishek Kandwalen_US
dc.contributor.authorQuingsha Chengen_US
dc.contributor.authorHongJian Shien_US
dc.contributor.authorIgbe Tobore and Zedong Nieen_US
dc.date.accessioned2020-03-12T16:54:36Z-
dc.date.available2020-03-12T16:54:36Z-
dc.date.issued2019-
dc.identifier.urihttp://epub.vgu.edu.vn/handle/dlibvgu/79-
dc.description.abstractNon-invasive blood glucose monitoring at microwave frequencies is generally thought to be unreliable in terms of reproducibility of measurements. The failure to reproduce a blood glucose measurement from one experiment to another is in major part due to the unwanted interaction of leaky waves between the ambient environment and the blood glucose measuring device. In this work, we have overcome this problem by simply eliminating the leaky modes through the use of surface electromagnetic waves from a curved Goubau line. In the proposed methodology, a fixed volume of blood-filled skin tissue was first formed by vacuum suction and partially wound with a curved Goubau line which was coated with a 3 mm thick layer of gelatin/glycerin composite. Blood glucose levels were non-invasively determined using a network analyzer. At 4.5 GHz, a near-linear correlation exists between the measured S12 parameters and the blood glucose levels. The measured correlation was highly reproducible and consistent with the measurements obtained using the conventional invasive lancing approach. The findings of this work suggest the feasibility of non-invasive detection of left and right imbalances in the body. 662-670en_US
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.ispartofseriesElectronics;Vol. 8(6)-
dc.subjectGoubau lineen_US
dc.subjectNon-invasive blood glucose measurementen_US
dc.subjectAcu-checken_US
dc.subjectLanceten_US
dc.subjectLeaky wavesen_US
dc.subjectSurface wavesen_US
dc.titleNon-invasive blood glucose monitoring using a curved goubau lineen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/electronics8060662-
dc.relation.journaltypeSCIE Q1en_US
item.languageiso639-1other-
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:ARTICLE/BOOK PUBLICATION
Files in This Item:
File SizeFormat
Non-invasive Blood Glucose Monitoring Using a Curved Goubau Line.pdf1.88 MBAdobe PDFView/Open
Show simple item record

Page view(s)

140
checked on Oct 30, 2025

Download(s)

109
checked on Oct 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric


Items are protected by © Copyright of Vietnamese - German University Library

© Copyright 2020 by Vietnamese - German University Library.
Add: Ring road 4, Quarter 4, Thoi Hoa Ward, Ben Cat City, Binh Duong Province
Tel.:(0274) 222 0990. Ext.: 70206